Corporate Headquarters:

Staticworx™, Inc.
124 Watertown Street
Watertown, MA 02472

Phone: 617-923-2000
Fax: 617-923-2009

US Mail Address:
PO Box 590069
Newton, MA 02459

Manufacturing and Warehouse:
Staticworx™, Inc.
Hwy 41
Calhoun, Georgia

West Coast Distribution Center:
Los Angeles, California
 
 

Staticworx™ Rubber Tile and Sheet Flooring: Colors

 

Staticworx™ EC Series ESD Conductive Rubber Flooring

Cleanroom ESD FlooringFault tolerant static control flooring. The first resilient flooring product that is both conductive and anti-static.

Whether you’re complying with NFPA, EIA or ANSI standards, Staticworx™ EC rubber safely meets all international standards for static control flooring applications. Staticworx™ EC rubber grounds out static and also prevents static in the first place. Easy to maintain, never needs conductive wax. No plasticizers and halogen-free. Resistant to chemicals and hot solder. Slip resistance in compliance with ADA guidelines. Provides anti-static surface in any environment from banking data centers to NASA grade clean rooms.

Staticworx™ EC Series ESD Rubber Flooring: Ideal for R & D labs, computer rooms, Hospitals, Data Centers,  electronics manufacturing and testing-repair areas.
Thickness = 2.0 mm
Tile Size available = 24 in. x 24 in.

Roll Size available = 39.3 ft. x 4 ft.
Easier to work with than vinyl- flash vinyl cove.

3 colors to choose from:

Contata

Presto

Largo

Due to variations in printed materials and computer monitor displays, color shown may not be exact. For true accurate color, please email Staticworx™ to request an actual sample,
or call (617) 923-2000.

*Non-stock colors require minimum orders. Contact a Staticworx™ representative for details.

Click here for a PDF spec sheet of Staticworx™ EC

Click here for larger view of Staticworx™ EC Series ESD Rubber flooring colors

 

Staticworx™ EC Series ESD  Rubber Flooring

What is Staticworx™ EC?

Rhino Rubber ESD Tile in an office environmentThe first rubber ESD tile and sheet flooring material that meets all the electrical parameters of ANSI/ESD S20.20-2007 but can also be used in real world environments like data centers, computer rooms and other spaces where footwear can not be controlled.

Most people do not realize that static dissipative tile will not meet the recommended system resistance limits of ANSI/ESD S20.20-2007. Typical single layer rubber flooring usually provides an electrical resistance that is in the upper spectrum of the range commonly known as static dissipative. This creates a real dilemma for companies trying to stay current or ahead of increasingly demanding ESD standards. According to ANSI/ESD S20.20-2007, the recommended floor and footwear system resistance tested per ESD STM97.1 should measure less than 35 meg ohms (3.5X106). That isn't possible for single layer ESD rubber floors; single ply dissipative rubber lacks the inherent conductivity to meet this parameter. Staticworx™ EC rubber is conductive and meets all current standards.

How do most ESD rubber suppliers meet ANSI/ESD S20.20-2007?

Single ply rubber floors meet only one portion of ANSI/ESD S20.20-2007 based upon low walking body voltage parameters. If a floor exhibits less than 100 volts of walking body voltage using controlled footwear that floor can theoretically claim compliance with ANSI/ESD S20.20-2007. However, meeting walking body voltage but not system resistance causes severe compliance issues for the quality department during routine certifications and plant audits. Walking body voltage is cumbersome and difficult to measure and monitor and require sophisticated expensive testing methods. It is much easier for owners to test and re-qualify their floors using resistance measuring equipment; Non-technical staff members can easily perform resistance tests and the equipment is portable and inexpensive. Walking body voltage is measured using charge plate monitors and should always be evaluated using statistical analysis since there are a number of intervening variables. The Staticworx™ EC Series was developed to comply with all recommended electrical parameters of ANSI/ESD S20.20-2007 and not just meet the requirements through a loop-hole like walking body voltage. With Staticworx™ EC there is no compromise. Staticworx™ EC rubber is the only ESD flooring that can inhibit static generation on people who neglect to wear their special ESD footwear.

Will Staticworx™ EC rubber reduce walking body voltage on people?

Staticworx™ EC will keep walking body voltages below 10 volts when used in conjunction with controlled footwear. But, Staticworx™ EC will also prevent significant accumulation of static even in situations where grounded footwear is forgotten or not used – like data centers and clean rooms. Staticworx™ EC is not just a conductive floor for advanced electronics assembly. It is also the best fit for any environment where static could interfere with the performance of computers. Ask us for the independent test reports about and take the time to read the study that led to the development of the first fault tolerant ESD flooring material.

Two layer vulcanized construction combines the advantages of a truly anti-static surface that can be used in any application regardless of footwear or relative humidity.

  • Designed for class Zero ESD flooring applications.
  • Low electrical resistance.  
  • Walking body voltage is less than 10 volts at extremely low relative humidity.
  • Available in tiles or sheet goods. 
  • Prevents accumulation of charges on people wearing regular footwear.
  • Ergonomic
  • Lifetime static control warranty
  • Manufactured with Stainblock process for easy maintenance.

 

 

Please contact an ESD Rubber flooring representative for an actual sample.

 

Architectural "Staticworx™ SD" Rubber ESD Tile:

Staticworx™ SD Rubber ESD Tile

Rhino ESD Tile in placeStaticworx™ SD Rubber ESD Dissipative Tile is designed for moderate mission critical environments where static might cause problems or interruptions with computers. Staticworx™ SD rubber is an attractive hammered product available in six stock colors that would please the most discerning architect or designer. Tough, yet visually appealing, Staticworx™ SD Rubber ESD flooring is perfect for hospitals, recovery rooms, universities, schools, emergency response centers, banks, conference rooms and anywhere comfort, performance and durability are needed.

Static generation less is than 100 volts according to ESD STM 97.2 (tested with conductive shoes). Staticworx™ SD Rubber ESD Flooring is resistant to most oils and grease. Easy to maintain, never needs conductive wax. Slip resistance in compliance with ADA guidelines. Exclusive StainBlock feature for easy maintenance.                       

Please note: For critical static control applications we do not recommend Staticworx™ SD rubber.

Tile Size available = 39.37 in. x 39.37 in.

Due to variations in printed materials and computer monitor displays, color shown may not be exact. For true accurate color, please email Staticworx™ to request an actual sample, or call (617) 923-2000.

*Non-stock colors require minimum order size. Contact a Staticworx™ representative for details.

Click here for larger view of Staticworx™ SD Rubber ESD Flooring

*Staticworx™ rubber is also available without static control properties.

Tile Size available = 24 in. x 24 in.

Available Colors:

Kilimanjaro
6203
Kilimanjaro

Congo Rubber Tile
6204
Congo

Botswana
6205
Botswana

 

Zanzibar
6206
Zanzibar

Omo Blue
6207
Omo Blue

Rainforest
6208
Rainforest

Please contact an ESD tile Rubber flooring representative for an actual sample.

Due to the variations in monitors and the limitations of web imagery, colors may not be accurate representations of actual floor product.

Click here for a pdf spec sheet of the Staticworx™ Rubber ESD Flooring

Staticworx™ Rubber is also available without static control properties

*Note: You will need Adobe Acrobat Reader to view these pdf files
Acrobat

 

 

Web Design Company

Solving ESD flooring problems for over 30 years, Staticworx™ installs dissipative flooring with proven antistatic capabilities. Call centers, data centers, computer rooms all need the protection provided by anti static vinyl, rubber tile or carpeting.